SigenStack BC cable now offered in an 8m length

Sigenergy issued a product change notice on 13 August 2026 introducing an 8m SigenStack BC cable kit alongside the existing 4m version. The longer kit carries the same electrical specification and connection types, and is scheduled for release on 30 August 2026. It removes a layout constraint on commercial and industrial installations where the battery controller and the inverter cannot be positioned close together.

Card showing the new 8m SigenStack BC cable kit and its 30 August 2026 release date

Sigenergy issued a product change notice dated 13 August 2026 introducing an 8m version of the SigenStack BC cable. The existing 4m kit remains available and is unchanged.

The SigenStack BC cable connects the SigenStack Battery Controller to Sigen C&I Hybrid inverters in the HYA and HYB series, carrying both power and communication signals between the two devices. The manufacturer states that the standard 4m cable covers most conventional installations, where the battery controller and the inverter sit close to one another, and that the 8m kit is intended for layouts where the two devices are positioned further apart.

The longer kit changes length and nothing else

The manufacturer describes the 8m kit as an extended-length version of the standard cable. It lengthens the two power cables and the single communication cable to 8m, while keeping the same electrical specifications and connection types as the 4m version.

The two kits are identified as follows in the notice.

Product codeProductKit box dimensions (W/D/H, mm)WeightAvailability
11182010SigenStack BC Cables 8m397 / 393 / 26923.81kg30 August 2026
11180009SigenStack BC Cables 4m397 / 393 / 18412.75kgAvailable now

The notice records that the stated dimensions and weights are those of the installation kit packing box, not of the cable itself.

Installation planning is where this matters

A fixed 4m interconnect sets a hard limit on how far apart the battery controller and the inverter can be placed. On commercial and industrial sites, switchboard position, wall space, ventilation clearances and access requirements often decide equipment placement before cable runs are considered. Where those constraints have previously forced a compromise, the 8m kit gives a second option from 30 August 2026.

The change does not alter the electrical specification, the connection type, or any clearance or installation requirement published for the connected equipment.

The applicable documents remain the controlling reference

This article is a dated record of a manufacturer notice. It is not an installation instruction and does not replace the current product documentation.

Installers should confirm the exact product code, the current manual for the specific equipment on site, and any subsequent manufacturer notice before ordering or commencing work. Sigenergy states in the notice that it excludes representations and warranties relating to the file and its contents. Current package documents, manufacturer instructions, licensing requirements and controlled work procedures apply to the specific task, and any conflict should be resolved before the equipment is installed or returned to service.